Solar Ownership

Solar Inverter Not Working: Causes, Fixes and When to Call a Pro

Solar Inverter Not Working: Causes, Fixes and When to Call a Pro

Inverter failure is one of the most frequent causes of lost solar production. Here is how to diagnose it safely and get it fixed.

When a solar inverter is not working, the cause is often simple: a tripped breaker, a switch left off, a grid outage or a lost internet connection that only makes the system look dead. If those basic checks don't bring it back, the inverter may have a real fault, and the fix is usually a warranty claim handled by your installer or a certified repair company.

This guide walks through the safe checks a homeowner can do, what the warning lights mean, what repairs cost and how warranties apply.

Key takeaways

  • Start with the safe basics: breakers, the inverter's on/off switch, a utility outage and your monitoring connection.
  • EnergySage notes that losing the internet connection is perhaps the most common way an inverter appears to "fail."
  • Inverter failure is one of the most frequent causes of lost solar production, according to NREL's O&M best-practices guide (December 2018).
  • Manufacturer warranties usually cover the part, but many do not pay for the labor to swap it.
  • Never open an inverter or touch DC wiring. Panels make power whenever there is daylight.

What an inverter does and why it matters

Your panels make direct current (DC). Your home and the grid use alternating current (AC). The inverter converts one to the other. If it stops, your panels may still be sitting in the sun, but no usable power reaches your house or the meter.

Homes use one of three main setups:

  • String inverter: one box, usually on a garage wall or near the electrical panel, handles all the panels.
  • String inverter with optimizers: a central inverter plus small devices under each panel.
  • Microinverters: a small inverter under each panel, with a gateway or combiner box that reports data.

The type matters for troubleshooting. A failed string inverter usually takes the whole system offline. A failed microinverter usually knocks out one panel, which is easy to miss without monitoring. For a deeper primer, see what a solar inverter does.

Common reasons a solar inverter is not working

It is offline, not broken

In a 2019 explainer, EnergySage said that perhaps the most common way an inverter "fails" is simply losing its internet connection. Production may be normal while your app shows zero. A new router, a changed Wi-Fi password or a new internet provider can all cause this. Enphase's support library, for example, points owners to check whether their Wi-Fi password or internet provider has changed when a system stops reporting.

A breaker or switch is off

Solar systems connect through a breaker in your main panel and often an outside AC disconnect. After electrical work, a storm or a power surge, one of these can be off. Many string inverters also have their own on/off switch.

The grid is down or out of range

Grid-tied inverters are designed to shut off when utility power is missing or out of range. The trip limits follow the IEEE 1547 standard, and SolarEdge's North American installation guide notes that utility authorization is required to change those set points. So during an outage, a standard grid-tied system without a battery will stop producing. That is normal, not a fault.

A real hardware fault

EnergySage's August 2025 repair guide says a sudden dip in production is often an inverter issue, likely caused by overheating, electrical surges or improper installation. A 2020 NREL field study of about 100,000 US residential, commercial and utility-scale systems, summarized by EnergySage, found inverter failures were the most common cause of larger system issues. EnergySage linked many of those problems to poor installation and noted that inverters need to be shaded for maximum longevity.

Ground faults and arc faults

Inverters watch for insulation problems and arcing in the DC wiring and shut down if they detect them. These errors often point to damaged wiring, a wet connector or chewed cables. They need a professional. Read more in our guide to ground fault and arc fault errors.

Safe checks to try when your solar inverter is not working

  1. Check the time and weather. Inverters sleep at night and may show little output at dawn, dusk or under heavy cloud.
  2. Look at the status lights or screen. Note any error code and take a photo.
  3. Check for a utility outage. If your neighbors are dark too, wait for the grid to return.
  4. Check breakers. Look for a tripped solar breaker in your main panel. If it trips again after you reset it, stop and call a pro.
  5. Check the internet link. Restart your router and reconnect the inverter or gateway to Wi-Fi using the manufacturer's app instructions.
  6. Compare with your meter. If your utility meter shows exports during sunny hours, the system is producing and only the monitoring is down.

Do not open the inverter cover, unplug panel connectors or climb on the roof. SolarEdge's installation guide tells installers to switch off the unit and wait five minutes before opening the cover because stored energy in capacitors can shock. That is a job for trained people.

Solar inverter not working? What the warning lights mean

Lights and codes differ by brand, so always check your manual. As one example, SolarEdge's 2019 installation guide for its HD-Wave inverters with SetApp lists these indications:

Light (SolarEdge HD-Wave example)Meaning per the manualWhat you can do
Green onSystem is producing powerNothing; check app if data is missing
Green blinkingAC connected but not producingCheck the on/off switch, time of day and weather
Blue onCommunicating with the monitoring platformIf blue is off, check Wi-Fi or network
Red onSystem errorWrite down the code and call your installer or a certified pro

Enphase, Tesla, SMA and other brands use their own lights and app messages. Your installer's paperwork or the manufacturer's US support site should explain them.

Warranty coverage and repair costs

Most inverter faults are warranty issues, but coverage has limits. Based on EnergySage's warranty comparison (updated September 2024):

  • Enphase microinverters carried a 25-year product warranty; labor was not covered.
  • SolarEdge inverters carried 12 years and its power optimizers 25 years; labor was not covered.
  • Tesla's inverter carried 12.5 years. The 2024 table lists Tesla labor as not covered, but EnergySage's August 2025 repair guide says Tesla's standard warranty covers inverter labor while Enphase's does not, so confirm in your own warranty document.
  • SMA string inverters carried 10 years, and labor was listed as covered.

The same comparison notes that most manufacturers will not cover damage from extreme weather (homeowners insurance may), and it suggests checking whether you must use a certified installer to keep coverage. EnergySage's repair guide adds that tampering with equipment yourself can be dangerous and may void your warranty. Your installer's workmanship warranty may cover the labor even when the manufacturer does not.

On cost, EnergySage's August 2025 guide says to expect around a couple of hundred dollars for a service visit if your warranty does not cover labor. For a full out-of-warranty replacement, NREL's 2018 O&M guide, citing 2018 estimates, listed replacement costs of about $0.25 per watt for string inverters (estimated as twice the factory price) and $0.40 per watt for microinverters. For a 7 kW system, that works out to roughly $1,750 and $2,800. Treat those as older planning figures; get current quotes. See our breakdown of inverter replacement cost.

NREL's guide also notes that some string inverter makers can take up to about a month to send a warranty replacement, so report problems early.

When to call a pro, and who to call

Call for help if any of these apply:

  • A red light, error code or "fault" message that does not clear after the basic checks.
  • The solar breaker trips again after one reset.
  • Burning smells, buzzing, scorch marks or water inside the inverter.
  • One or more panels show zero in a microinverter or optimizer system.
  • Production is far below the same month last year with similar weather.

Start with your original installer. If you don't know who that is, EnergySage suggests looking for a sticker on the inverter or junction box. If the installer has closed, contact the inverter manufacturer, which EnergySage says can point you toward installers who work in your area. Our solar orphans hub explains your options when the company that sold your system is gone, and you can check a company's track record in our solar company directory.

If you lease your system or have a power purchase agreement, call the leasing company first. The Department of Energy notes that most lease and PPA arrangements require the installer to provide system maintenance.

A note on tax credits for repairs

The federal Residential Clean Energy Credit does not help with inverter repairs or replacements done now. According to the IRS's energy credit FAQs, the credit is not allowed for expenditures made after December 31, 2025, and an expenditure counts as made when installation is completed. Check your state energy office for any local programs, but don't budget on a federal credit.

Next steps

Run the safe checks above, take photos of any error codes and call your installer or the manufacturer. If your monitoring is the only thing that went dark, our guide to monitoring that stopped working walks you through reconnecting it.

Frequently asked questions

Why does my solar inverter say it is offline?

Usually the inverter or its gateway has lost its internet connection, often after a router change or Wi-Fi password change. The system may still be producing power, so check your utility meter for exports during sunny hours.

Can I reset my solar inverter myself?

You can safely check breakers and use the external on/off switch or the steps in your owner's manual. Do not open the inverter or disconnect panel wiring, because the DC side can stay energized in daylight.

Does a solar inverter work during a power outage?

A standard grid-tied inverter shuts off when grid power is lost, which is a safety feature. You only get power during an outage if your system has a battery or backup setup designed for it.

Is a broken solar inverter covered by warranty?

The part is usually covered for 10 to 25 years depending on the brand, but many manufacturers do not pay for labor. Your installer's workmanship warranty may cover the labor, so check both documents.

How long do solar inverters usually last?

EnergySage says central string inverters last about 10 to 15 years, while microinverters generally last about as long as the panels. Warranty length is a useful guide to expected life.

Sources

Related guides

Questions and comments

Be the first to ask a question or share your experience.

Comments are checked before they appear. No links or advertising. Guidelines.

Calculators for this topic

More solar ownership guides

All solar ownership guides →