A solar inverter display tells you three main things: whether the system is producing power, whether it is talking to the monitoring service, and whether there is an error. On many inverters a steady green light means production, a communication light (blue or yellow on SolarEdge models) shows data is flowing, and a red light means a fault that needs attention.

Exact meanings vary by brand and model, so always confirm with your own manual. This guide uses published SolarEdge and Enphase manuals as worked examples.

Key takeaways

  • On a SolarEdge HD-Wave inverter, green on means producing, green blinking means AC is connected but not producing, blue on means communicating with monitoring, and red on means a system error.
  • Older SolarEdge inverters with an LCD screen show Vac (AC voltage), Vdc (DC voltage), Pac (AC output power) and counters for daily, monthly, yearly and lifetime energy.
  • Enphase microinverters have their own status light: flashing green is normal, flashing orange means no communication with the IQ Gateway, flashing red means a grid problem and solid red means a DC fault condition.
  • No light at night is normal. A red light, or no production on a sunny day, is not.
  • Do not open the inverter cover. Reading the display is safe; repairs are for qualified technicians.

Where to find your solar inverter display

Your inverter type decides where you look.

  • String inverter: a box on a wall, usually near your electric meter or in the garage. Its lights or screen cover the whole system.
  • Microinverters: small units under each panel. Each has a status light, but you usually cannot see it from the ground, so the app and the gateway are your main tools.
  • Hybrid or battery inverter: often shows status in the app rather than on a screen.

Not sure which you have? Our explainer on microinverters vs string inverters shows how to tell them apart.

Reading the status lights on a SolarEdge inverter

SolarEdge's HD-Wave installation guide for North America (version 1.1, February 2019) describes three status lights on inverters that use the SetApp mobile app instead of a built-in screen:

LightStateMeaning (per SolarEdge guide)What to do
GreenOnThe system is producingNothing
GreenBlinkingAC is connected but the system is not producingNormal at night or very low light; check the ON/OFF switch on a sunny day
BlueOnThe inverter is communicating with the monitoring platformNothing
RedOnSystem errorNote the time, check the app, contact your installer

The same guide says green blinking is also used during service work to show that DC voltage has dropped to a safe level, below 50 volts. That is a technician's check, not something a homeowner needs to test.

Older SolarEdge inverters with three lights

SolarEdge's North American user manual for its earlier single- and three-phase inverters (MAN-01-00133) uses green, yellow and red lights. Green on means producing, green blinking means standby, and green off means not producing, such as at night, with the switch off, or during an error. Yellow blinking means monitoring data is coming in from a power optimizer, or the inverter is shutting down. Red on means an error.

Reading an inverter LCD screen

Some older string inverters have a small LCD screen. In the SolarEdge user manual above, pressing the external LCD light button turns on the backlight, and further presses step through status screens. The main screen shows:

  • Vac [V]: the AC output voltage, which tracks your grid voltage.
  • Vdc [V]: the DC input voltage coming from the panels.
  • Pac [W]: the AC power the inverter is producing right now.
  • P_OK: XXX/YYY: how many power optimizers sent data in the last two hours (XXX) out of how many are paired (YYY). If XXX stays well below YYY on a sunny day, some optimizers may not be reporting.
  • S_OK: shown when the connection to the SolarEdge monitoring portal is working.
  • ON/OFF: the position of the inverter's ON/OFF switch.

An energy screen shows production for the day, month, year and since installation. That lifetime total is handy when you compare actual vs estimated solar production.

The manual also lists operating states. "Production" means the inverter is producing power. "Waking Up" shows a countdown before production starts, and night mode is the normal power-off state after dark.

Reading Enphase microinverter status lights

Enphase's IQ8 Installation and Operation Manual (January 2024) lists these status light meanings for each microinverter:

  • Flashing green: normal operation. The grid is normal and the microinverter is communicating with the IQ Gateway.
  • Flashing orange: the grid is normal, but there is no communication with the IQ Gateway.
  • Flashing red: the grid is not present or not within specification.
  • Solid red: an active "DC Resistance Low, Power Off" condition, a DC-side fault that the manual says must be reset using its DC Resistance Low procedure. That is a job for your installer or a technician.

Because these lights sit under the panels, most Enphase owners rely on the Enphase app, which shows each microinverter's output. A panel that reports zero while its neighbors produce is the app equivalent of a red light. Our guide on what to do about a microinverter failure picks up from there.

Warning signs on your inverter display

Use this checklist when you glance at the inverter:

  • Red light on, or an error message: write down the code or take a photo, then check your app.
  • No green light at midday on a sunny day: check that the inverter's ON/OFF switch and AC breaker are on.
  • Communication light off for days: production may be fine, but you are flying blind. See what to do when solar monitoring stops working.
  • Power reading far below normal for the season: compare with the same week last year in your app.
  • Repeated error after a reset: stop resetting and call for service.

Some errors relate to ground faults or arc faults, which are safety shutdowns. Your installer can tell you which ones you may safely reset and which need a site visit.

When to call a pro, and what it may cost

Reading the display is safe. Opening the inverter is not. SolarEdge's guide tells installers to wait five minutes after switching off before opening the cover, because stored energy remains. Leave that to a licensed technician.

Call your installer or a solar repair company if a red light or error returns, if production is zero on a sunny day after you have checked the switch and breaker, or if you smell burning or see damage. Tell them your inverter model, the light pattern or code, and when it started.

Costs depend on what is wrong. SolarReviews' 2026 inverter cost guide (checked November 2026) puts the average cost to replace a home solar inverter at $350 to $3,500 including labor, with string inverters typically costing $1,000 to $3,000 to buy. Check your warranty first. Enphase's US warranty, for example, covers IQ8 microinverters for up to 25 years from activation, while gateways and similar communication devices generally carry 5 years. Labor is not covered by that warranty, so ask your installer what their workmanship warranty includes. Our inverter warranty comparison has more detail.

Next steps

Photograph your inverter's lights on a normal sunny day so you have a baseline. If the display ever shows a fault and your installer has closed, our solar orphans guide explains how to get service from the equipment maker or an independent repair company.

Frequently asked questions

What does a green blinking light on a SolarEdge inverter mean?

On SolarEdge HD-Wave inverters, green blinking means AC is connected but the system is not producing. That is normal at night or in very low light.

What does a red light on my solar inverter mean?

On the SolarEdge and Enphase equipment we reviewed, red indicates a system error, a grid problem or a DC fault condition. Note the code, check your app and contact your installer if it does not clear.

Why is my inverter display blank at night?

Inverters stop producing when there is no sunlight, and many switch off their screens or lights. SolarEdge calls this night mode, and it is normal.

What do Vac, Vdc and Pac mean on a solar inverter?

In SolarEdge's manual, Vac is the AC output voltage, Vdc is the DC input voltage from the panels, and Pac is the AC power being produced right now.

What does flashing orange mean on an Enphase microinverter?

Enphase's IQ8 manual says flashing orange means the grid is normal but the microinverter is not communicating with the IQ Gateway.