Solar System Inspection Checklist: Your Annual Solar Checkup, Step by Step
A once-a-year solar checkup split into owner checks you can do from the ground and technician checks that need tools, with costs and warranty notes.
A solar system inspection checklist covers three areas once a year: production data, a visual check of the array and equipment, and electrical and mounting checks done by a qualified technician. You can handle the first two from the ground in under an hour. The electrical and roof work belongs to a pro, and published prices for a standalone inspection run about $150 to $350.
Key takeaways
- Start with your data: compare this year's production with last year's and with your installer's estimate.
- Do visual checks from the ground or a window. Panel makers say never to step on modules.
- A technician should check wiring, connectors, inverter terminals, mount bolts and roof flashing.
- Book an extra inspection after hail, high winds or heavy snow. At least one panel maker's manual requires it.
- Keep a written record each year. It helps with warranty claims and when you sell the house.
Why an annual solar system inspection matters
Solar systems have few moving parts, but they sit outside for decades. The U.S. Department of Energy's Federal Energy Management Program (FEMP) notes that panel output slowly drops with age, "often about 0.5% per year," and that failure rates rise as equipment ages. A yearly check helps you tell normal aging from a real fault.
Many companies expect it, too. South Carolina's state Energy Office says "most vendors recommend a yearly maintenance check by the installer." Qcells' North American installation manual (revision 09, March 2025) says the system "has to be inspected regularly by certified personnel," and that the timing "can depend on local circumstances."
For homes, the job usually falls on you. The national lab's O&M guide (from the lab formerly called NREL, now the National Laboratory of the Rockies) says inspections of small residential systems "are the responsibility of the contract offtaker," meaning the customer who uses the power. For most homes that is you, unless a lease or PPA says otherwise.
Part 1: Owner checklist (no ladder needed)
Production data
- Pull 12 months of production from your monitoring app or inverter screen.
- Compare each month with the same month last year. A cloudy spring can explain a small dip; a steady gap cannot.
- Compare the yearly total with your installer's estimate, or run your address through the free PVWatts calculator from the National Laboratory of the Rockies at pvwatts.nlr.gov.
- With microinverters or optimizers, look for any single panel that reports much less than its neighbors.
- Note any error codes or alerts from the past year.
Visual check of the array
- Use binoculars from the yard or a window. Look for cracked glass, discoloration, or heavy dirt and droppings.
- Look under the panel edges for nests, leaves or twigs. FEMP lists removing animal nests and debris as routine work.
- Check for new shade from trees. The lab's guide says owners must keep up "routine bush and shrub trimming."
- Look for cables hanging below the array or rubbing on the roof.
Inverter and equipment check
- Confirm the status light is normal. Write down any code on the screen.
- Make sure vents and fins are clear of dust, spider webs and stored items.
- Look for rust, cracked conduit or loose covers on the inverter, disconnect switch and meter area.
- Confirm the monitoring login still works. FEMP notes that monitoring can lapse when "passwords are lost," and advises archiving passwords and key files; store yours with your system papers.
Inside the house
- Check the attic under the array, and the ceiling below it, for water stains after a rainy season.
Part 2: Technician checklist
These checks involve the roof or live electrical parts, so leave them to a qualified solar technician or electrician. Panels create voltage whenever light hits them.
| Item | What the technician checks | Why it matters |
|---|---|---|
| Wiring and wire management | Cables secured and protected; brittle plastic ties replaced | The lab's guide says preventive work means "making sure wires are secure and protected." FEMP flags plastic ties as prone to early failure. |
| Connectors | Fully seated and locked, no burn marks | SolarEdge says arcs can occur when connectors or cables are improperly connected or damaged. |
| Inverter terminals | Re-torque screw lugs; thermal scan of connections | Both are listed in the lab's inverter maintenance guidance. |
| Racking and mount bolts | Bolts and panel clamps checked with a torque wrench | DOE's Building America Solution Center advises an annual tightness check. |
| Roof flashing | Seals and flashing around each mount intact | Mounts are roof penetrations; sealant alone can break down in sunlight. |
| Grounding and fault history | Ground connections intact; review any ground-fault trips | FEMP: after nuisance tripping, inspect for ground faults rather than just restarting. |
| Thermal imaging (optional) | Infrared scan of panels for hot spots | The lab's guide notes aerial thermal imaging can be part of annual preventive maintenance. |
Extra checks after storms and extreme weather
Do not wait for the yearly visit after a big storm. Qcells' manual says inspections must happen "especially after extraordinary events (e.g. storm, hail, high snow loads etc.)." After severe weather:
- Look at your production the next sunny day.
- Photograph any visible damage from the ground.
- Call your installer or a service company for an inspection.
- If there is damage, call your insurer before any repairs start. See our guide to hail damage to solar panels.
Red flags that should not wait for the annual checkup
Your yearly checklist is for routine care. Some problems need a call the same week:
- A sudden drop in output. EnergySage notes a sudden dip is often an inverter issue. If the app shows zero, first rule out a lost internet connection.
- A fault that keeps coming back. FEMP's guidance is clear: after an inverter trips, inspect for ground faults. "Do not just turn the system off and on."
- Water stains on the ceiling or attic deck under the array.
- Hail larger than about an inch. A national lab study reported by Utility Dive in February 2024 found long-term output losses begin when hailstones exceed roughly 1 inch, and that each severe weather event cut a system's yearly output by about 1% on average.
- Burning smells, buzzing or scorch marks. Turn nothing on or off yourself beyond your installer's shutdown steps; call a pro.
Our guide on why a solar system produces less power helps you sort normal dips from real faults.
What a professional solar inspection costs
HomeGuide lists $150 to $350 for an inspection that is not included in your installation service contract (checked November 2026; the page shows no date). Some installers include a yearly check in their warranty package, and EnergySage advises asking whether that visit costs extra. If you have a lease or PPA, the Department of Energy says most such contracts require the installer to provide system maintenance, so check yours first. For a full budget, see our page on solar maintenance cost per year.
Warranty tips for your annual checkup
- Use certified people. Equipment warranties often exclude damage from unauthorized service. Enphase's IQ8 warranty, for one, excludes damage from service by anyone who is not an Enphase representative.
- Do not modify panels. Qcells' manual says not to drill extra holes and lists unauthorized modification as misuse that voids the limited warranty.
- Clean gently, if at all. The same manual says to clean only cooled panels, avoid water when frost is possible, and never use abrasives or solvents.
- Keep records. Save the inspection report, photos and production numbers each year.
If your installer has gone out of business, you can still get inspections. See our solar orphans guide.
Next steps
Put a yearly reminder on your calendar, ideally before your sunniest season. Do Part 1 yourself, then book a technician for Part 2 every year or two, and after any big storm. To find a service provider, start with our solar company reviews.
Frequently asked questions
How often should a solar system be inspected?
Once a year is a common recommendation, and South Carolina's Energy Office says most vendors recommend a yearly check by the installer. Add an inspection after hail, high winds or heavy snow.
What does a solar inspection include?
A good inspection reviews production data, looks for physical damage, checks wiring and connectors, re-checks mount bolts and roof flashing, and reviews inverter fault history. Some include a thermal scan for hot spots.
How much does a solar panel inspection cost?
HomeGuide lists about $150 to $350 when inspection is not included in your service contract. Some installers include it in their warranty package.
Can I inspect my own solar panels?
You can check production data and look at the array from the ground. Leave roof work and electrical checks to a qualified technician, since panels produce voltage whenever light hits them.
How much should solar output drop each year?
Federal energy guidance says panel output typically declines about 0.5% per year. A drop that is much bigger than that, or sudden, is worth investigating.
Sources
- U.S. DOE FEMP – Operate and Maintain an Existing Photovoltaic System
- U.S. DOE FEMP – Optimizing Solar Photovoltaic Performance and Longevity
- NREL (now NLR) – Best Practices for O&M of Photovoltaic and Energy Storage Systems, 3rd Edition
- Qcells – Installation Manual Q.TRON M, North America, Rev09 (March 2025)
- DOE Building America Solution Center (PNNL) – Roof Anchor System for Solar Panels
- SolarEdge – Inverter Arc Detection Application Note, North America (v1.3, May 2018)
- South Carolina Energy Office – Warranties, insurance and maintenance
- Utility Dive – NREL study on severe weather and solar output (Feb. 1, 2024)
- EnergySage – When solar panel repair is needed (Aug. 2025)
- HomeGuide – Solar panel maintenance cost
- EnergySage – What are the costs of solar after installation? (Dec. 2023)
- Enphase – IQ8 Microinverter Limited Warranty (USA-Canada, effective Oct. 30, 2023)
- U.S. DOE Energy Saver – Planning a Home Solar Electric System
Questions and comments