A solar production estimate is a forecast of how many kilowatt-hours (kWh) a specific solar system should produce in a typical year at your address, based on its size, direction, tilt, shading and local weather history. It is a reasonable guide, not a guarantee: NLR's PVWatts Version 5 manual (2014) says annual estimates can be off by as much as plus or minus 10%, and any single year can swing further because of weather.
Because the production estimate drives every savings number in a solar quote, it is worth knowing how it is made and how to test it.
Key takeaways
- Production estimates use typical-year weather data, so real years will run above or below.
- NLR's 2014 PVWatts Version 5 manual cites possible errors up to about 10% for annual totals and 30% for monthly totals.
- Loss assumptions (shade, soiling, wiring and more) can change an estimate a lot; the 2014 PVWatts manual set a 14% default for total losses.
- Compare every quote's estimate against a free PVWatts run for the same system.
- Ask whether the installer guarantees any output in writing.
What goes into a solar production estimate?
Most estimates, whether from an installer's software or the free PVWatts tool from the National Laboratory of the Rockies (NLR, formerly NREL), combine the same inputs:
- System size in kilowatts (kW) of panel capacity.
- Location and weather data. PVWatts Version 8 uses typical meteorological year (TMY) weather data from the National Solar Radiation Database (NSRDB).
- Direction (azimuth) and tilt of each roof face.
- Shading from trees, chimneys and nearby buildings.
- System losses, such as dirt, wiring and equipment mismatch.
- Inverter efficiency and sizing.
DOE's Energy Saver lists the same ingredients for sizing a system: your site's solar resource, the system's orientation and tilt, and how efficiently it converts sunlight to electricity.
The default loss assumptions
Loss assumptions are where estimates quietly differ. The PVWatts Version 5 manual (published September 2014) lists these defaults, which combine to a 14% total. The current tool lets you change every value, so check the default it shows when you run it:
| Loss type | PVWatts default | When it might be higher |
|---|---|---|
| Soiling (dirt, pollen) | 2% | Dusty areas, low tilt, little rain |
| Shading | 3% | Trees or nearby structures |
| Snow | 0% | Snowy climates |
| Mismatch | 2% | Mixed panel orientations on one string |
| Wiring | 2% | Long wire runs |
| Connections | 0.5% | Poor connectors |
| Light-induced degradation | 1.5% | Depends on panel technology |
| Nameplate rating | 1% | Panels that test below their label |
| Age | 0% | Later years of operation |
| Availability (downtime) | 3% | Outages or slow repairs |
An installer using lower losses will show a bigger estimate for the same system. That is not necessarily wrong, but you should ask why.
How accurate is a solar production estimate?
NLR is direct about the limits. The PVWatts Version 8 page says its predictions include many inherent assumptions and uncertainties and do not distinguish between better- and lesser-performing panels. The Version 5 manual (2014) states that errors may be as high as plus or minus 10% for annual energy totals and plus or minus 30% for monthly totals, and that actual performance in a specific year may deviate from the long-term average by up to plus or minus 20% for the annual total. It adds that results should be read as a representative estimate for a similar system.
There is also evidence the model does reasonably well over a full year. In a June 2019 NLR conference paper comparing an improved PVWatts model with measured data from nine older operating PV plants, the average annual error was -1.9%, with individual plants ranging from +2.8% to -8.7%. The authors cautioned that additional validation is always warranted, and nine plants is a small sample.
Why monthly numbers miss more than annual ones
A cloudy month, a snowy week or a heat wave can push one month well off the forecast, but good and bad months tend to balance over a year. PVWatts Version 8 shows an expected range based on 30 years of actual weather at your location for this reason. Judge a new system on a full 12 months, not on its first month. See solar production by month for seasonal patterns.
How the production estimate drives your savings numbers
Almost every savings figure in a solar proposal starts with the production estimate. The installer multiplies the kWh the system should make by the value of each kWh, which depends on how much you use at home and how your utility credits exports. If the production number is 10% too high, every savings figure built on it is too high as well.
Then a second forecast is layered on top: future electricity prices. The FTC cautions that it is hard to predict future utility rates and suggests comparing any projection with your own bills and the output estimates in written bids. A sensible approach is to check the production number first, using PVWatts and your roof's real conditions, and only then look at the savings. Our guide to checking inflated savings estimates walks through the math.
Why real output can differ from the estimate
- Weather. Estimates use a typical year; your actual year is not typical.
- Unmodeled shade. A tree that grows or a new building next door changes things. DOE notes that online tools do not account for every variable.
- Downtime. A tripped breaker or failed inverter can erase weeks of production.
- Design changes. If the final installed layout differs from the quoted one, the estimate no longer applies.
- Degradation. Output declines slowly over the years; NLR research found a median of about 0.5% per year.
- Delayed start. Production before your utility's permission to operate does not count toward your bill.
Step by step: how to check a production estimate in your quote
- Find the numbers. Each bid should state system size (kW) and estimated annual production (kWh). DOE and the FTC both say bids should include expected output.
- Calculate the ratio. Divide annual kWh by system kW. Compare that ratio across quotes; a much higher figure for a similar roof deserves questions.
- Run your own PVWatts estimate. Enter the same size, tilt and direction. Start with the default losses, then add shading if your roof has it.
- Ask about assumptions. Request the loss, shading and degradation assumptions behind the installer's number.
- Compare with your usage. Check the estimate against 12 months of bills to see what share of your use it covers.
- Get guarantees in writing. The FTC suggests checking whether a contract guarantees a minimum output and how you are compensated if it falls short.
Our solar panel calculator can help with steps 2 and 5.
Common mistakes with solar production estimates
- Treating the estimate as a promise rather than a typical-year forecast.
- Comparing a first-month result with an annual average.
- Accepting a savings projection without checking the production number underneath it. The FTC notes it is hard to predict future utility rates, so savings figures stack two forecasts.
- Ignoring shade from trees that will keep growing.
- Not saving the original estimate, which you will need to compare against actual output later.
Questions to ask your installer about production
- What software produced this estimate, and what weather data does it use?
- What shading did you measure, and how?
- What total loss percentage did you assume?
- Does the estimate include panel degradation over time?
- Is there a production guarantee, and what happens if the system underperforms?
Once your system is running, use our guide to comparing actual vs. estimated production, and keep the original estimate on file.
Next steps
Gather your quotes and calculate kWh per kW for each one, then run them through the solar quote checker. If an estimate looks high, ask the installer for its assumptions, and compare installers in our solar company directory.
Frequently asked questions
How accurate are solar production estimates?
NLR's 2014 PVWatts manual says annual estimates can be off by up to about 10% and monthly estimates by up to about 30%, and a single year's actual output can differ from the long-term average by up to about 20%.
Why is my solar system producing less than estimated?
Common reasons include a cloudier-than-typical year, shade the estimate missed, equipment downtime or a final design that differs from the quote. Compare a full 12 months before drawing conclusions.
Is PVWatts accurate for home solar?
It is a widely used free starting point, but NLR says it includes many assumptions and does not distinguish between better- and lesser-performing panels. Treat it as a representative estimate.
What system losses should a solar estimate assume?
PVWatts' 2014 manual set a 14% total default that covers soiling, shading, wiring, mismatch, downtime and more. Shady or dusty sites may need higher losses.
Do solar installers guarantee production?
Some do and some do not. The FTC suggests checking whether the contract guarantees a minimum output and how you would be compensated if the system falls short.
Sources
- NREL (now NLR) – PVWatts Version 8: what's new and how the expected range works
- Dobos – PVWatts Version 5 Manual, NREL/TP-6A20-62641 (September 2014, archived copy)
- Dobos, Freeman & Blair – Improvements to PVWatts for Fixed and One-Axis Tracking Systems (NREL, June 2019)
- DOE Energy Saver – Planning a Home Solar Electric System
- FTC – Solar Power for Your Home
- NREL (now NLR) – Photovoltaic Degradation Rates: An Analytical Review (2011, via OSTI)
- DOE – Walk Me Through It: A Step-by-Step Guide for Consumers Going Solar (August 2021)
Questions and comments
Be the first to ask a question or share your experience.